Medical Equipment 3.5 Inch Portable Handheld NIBP Spo2 EtCO2 PC100E Vital Sign Monitor CE marked
Advantages:
- Smallest and exquisite handheld vital sign monitor
- Accurate measurement in 0.05% Low perfusion Index,the world leading production in the movement environment
- Provide the parameter of PI( Perfusion Index 0.05%-20%)
- Suitable all kinds of animals and human
- Easy operation by 3.5 inch color TFT
- Up to 100 users ID switch
- Two measurements mode:Spot, Monitoring
- Data storage function: support data review, date trend and chart
- In monitoring mode, can continuously record 48 hours of measurement data
- In spot mode, 100 users ID, each user can store 200sets data
- Support audio and visual alarm, support to set alarm upper and lower limit values
- Lithium ion battery power supply
- Optional Charging dock
Description:
Smallest Handheld Vital Sign Monitor in the world. The PC100E is mainly used to measure Blood Pressure, Spo2, Temperature and Pulse Rate. This monitor is suitable for adult, pediatric or neonatal patients, and could be applied in general ward, including, but not limited to, ICU, CCU or ambulance, and so forth.

Specifications:
Display | 3.5 inch color TFT |
Resolution | 320X480 |
Indicator | Alarm light, Power light |
Waveform | SPO2 and wavevalue |
Alarm | Sensor off, Low power |
Modes | Visual and Audio |
Application | Adult, Pedia/Child, Infant/Neonate/Newborn |
Oxygen Saturation (%SpO2)
*Measurement range:
SpO2:0-100% PR:0-300bpm
Perfusion index: 0.05%-20%
*Accuracy range:
SpO2 saturation: 70-100%
Pulse rate: 20-254bpm
Perfusion Index: 0.05%-20%
*Accuracy:
SpO2: ±2(70%-100%) Motion: ±3
Pulse rate: ±3bpm Motion: ±5bpm

CO2 *Measurement range:
ETCO2:0-150mmHg(0-19.7%)(0-20kPa)RB:3-150BPM *Accuracy range:
ETCO2 Range | Accuracy |
0-40mmHg | ±2mmHg |
41-70mmHg | ±5% of reading |
71-100mmHg | ±8% of reading |
101-150mmHg | ±10% of reading |
*Resolution: ETCO2:0.1mmHg RR:1BPM *Setting compensation parameters Pressure range: 450-850mmHg Oxygen range: 0-100% Equilibrium gas: N2O,He NIBP
*The wider NIBP measurement range | Adult | PED | NEO |
SYS | 40-270mmHg | 40-200mmHg | 40-135mmHg |
MEAN | 20-230mmHg | 20-165mmHg | 20-105mmHg |
DIA | 10-210mmHg | 10-150mmHg | 10-95mmHg |
Pulse rage range | 40-240bpm |
NIBP measurement accuracy | 3mmHg |
Pulse rate measurement accuracy | ≤2%(≥100bpm)or 2beats/min(<100BPM) |
Independent software protection pressure | | |
Adult:300mmHg | PED:240mmHg | Neo:150mmHg |
Independent hardware protection pressure | | |
Adult:320-330mmHg | PED:265-275mmHg | NEO:160-165mmHg |
Accessories:
PC100 Series products:
Packing:
Union Medical Product Line:
Factory:
Company Profile:
We, Wuhan Union Medical Technology CO., Ltd, is a R&D company in patient monitoring solutions, which started in 2009 with leading engineers in China, and established in 2013. Union Medical is committed to the techniques and products of monitoring, diagnosing ,supporting and treating the biological information; serving the society; improving human health.
Union Medical focused on the development of patient monitoring solutions with engineers who have experience in this area for more than 15 years. Our main solutions are about the non-invasive and invasive solutions for patients vital sign parameters, technologies as: algorithm for ECG diagnosis, pulse oxygen monitoring, respiration gas monitor, respiratory monitoring, electronic sphygmomanometer etc. Vital sign parameter modules: ECG module, SPO2 Module, NIBP Module, IBP Module, Six-parameter Module, Multigas Module etc.
We also produce our own final monitoring equipments, like ECG machines, patient monitors, vital sign monitors, pulse oximeters, ETCO2 monitors/Capnometer/Capnograph, Anesthesia Multigas monitors etc.